| NO | Produkte | CAS-nr. | Toepassing | Sleutelkwaliteitsaanwyser | ||||
| Suiwerheid | Isomeer | Spesifieke onsuiwerheid | *Maks1 | Vog | ||||
| 1 | Fmoc-3-(2-naftiel)-D-Ala-OH | 138774-94-4 | Meeste produkte | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
| 2 | Ac-3-(2-naftiel)-D-Ala-OH | 37440-01-0 | Meeste produkte | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
| 3 | Fmoc-3-(3-piridiniel)-D-Ala-OH | 142994-45-4 | Meeste produkte | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
| 4 | Fmoc-4-chloro-D-Phe-OH | 142994-19-2 | Meeste produkte | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
| 5 | Fmoc-D-Cit-OH | 200344-33-8 | Cetrorelix | ≥99.5% | ≤0.1% | ≤0.1% | ≤0.2% | ≤1.0% |
| 6 | Fmoc-D-Ala-OH.H2O | 79990-15-1 | Meeste produkte | ≥99.5% | ≤0.1% | ≤0.1% | ≤0.2% | ≤6.5% |
| 7 | Fmoc-D-Aph(tBuCbm)-OH | 1433975-21-3 | Degarelix | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
| 8 | Fmoc-D-Aph(Cbm)-OH | 324017-22-3 | Degarelix | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
| 9 | Fmoc-L-Aph(L-Hor)-OH | 1253282-31-3 | Degarelix | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
| 10 | Fmoc-L-Lys(iPr,Boc)-OH | 201003-48-7 | Degarelix | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
| 11 | Fmoc-N-Me-Tyr(tBu)-OH | 133373-24-7 | Abarelix | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
| 12 | Fmoc-D-Asn(Trt)-OH | 180570-71-2 | Abarelix | ≥99.0% | ≤0.2% | ≤0.3% | ≤0.3% | ≤1.0% |
| 13 | Fmoc-HomoArg(Et)2-OH.HCl | 1864003-26-8 | Ganirelix | ≥95.0% | ≤0.5% | ≤1.0% | ≤2.0% | ≤2.0% |
| 14 | Fmoc-D-HomoArg(Et)2-OH.HCl | 2098497-24-4 | Ganirelix | ≥95.0% | ≤0.5% | ≤1.0% | ≤2.0% | ≤2.0% |
| 15 | Fmoc-Lys(nikotinoïel)-OH | 252049-11-9 | Antide | ≥98.0% | ≤0.2% | ≤0.3% | ≤0.5% | ≤1.0% |
| 16 | Fmoc-D-Lys(nikotinoïel)-OH | 252049-12-0 | Antide | ≥98.0% | ≤0.2% | ≤0.3% | ≤0.5% | ≤1.0% |
* Maks1 = Maks Onbekende Onsuiwerheid
Ander aanwyser:
- Asynsuur: ≤0.02% (Alle Produkte)
- Etielasetaat: ≤0.5% (Alle Produkte)
- Alkohol: ≤0.5% (Alle Produkte)
TOC en geleidingsvermoë van hooftoevoer- en terugkeerpunte word periodiek gemonitor. TOC word weekliks deur kwaliteitskontrole gemonitor. Geleidingsvermoë word aanlyn gemonitor en elke vier uur deur die gesuiwerde waterstasie-operateur aangeteken. Die geleidingsvermoë word by die primêre RO, sekondêre RO, EDI en totale terugkeerpunt van die verspreidingstelsel gemonitor. Die spesifikasie van gesuiwerde water is in plek en voldoen aan die voorafbepaalde spesifikasie wat nie meer as 1.3 µs/cm by 25°C (USP) is nie. Vir hooftoevoer- en terugkeerpunte word 'n volledige toets elke week uitgevoer, vir ander gebruikspunte in die sirkulasielus word 'n volledige toets een keer per maand uitgevoer. Die volledige toets sluit eienskappe, pH, nitraat, nitriet, ammoniak, geleidingsvermoë, TOC, nie-vlugtige stowwe, swaar metale, mikrobiese limiete en bakteriële endotoksien in.